Genie GTH-636 Telehandler Maintenance Schedule

Genie GTH-636 Telehandler maintenance — the short answer

Genie GTH-636 Telehandler maintenance schedule by engine hours

IntervalServiceDetails
Every 1,000 hoursAir FilterEvery 1000 hours: replace air filter cartridge; Quarterly: inspect engine air filter
Every 1,000 hoursFuel FilterEvery 1000 hours: replace fuel filter cartridge; every 1000 hours: replace fuel pre-filter
Every 1,000 hoursLubrication PointsEvery 8 hours or daily, whichever comes first: lubricate the boom. Every 1000 hours: king pin bearings and bushings - grease; trunnion bushings - grease; seals - grease (severe duty perform daily). Quarterly: lubricate the driveshaft; inspect and lubricate the sequencing chains.
Every 1,000 hoursTransmission/Hydrostatic FluidEvery 1000 hours: transmission oil and filter - replace; drop box (gearbox) - change oil
Every 1,000 hoursBattery InspectionQuarterly: battery inspection; Every 1000 hours: battery and cable connectors - check
Every 2,000 hoursHydraulic Fluid & FilterEvery 50 hours, one time: replace hydraulic filters; Every 2000 hours: test or replace hydraulic oil. Recommended hydraulic fluid: Chevron Rando HD Premium, ISO Grade 32, viscosity index maximum 200

Genie GTH-636 Telehandler specifications

Genie GTH-636 Telehandler items without a fixed hour interval